1.3.1 In addition
to the information required by Vol 2, Pt 7, Ch 1, 2.1 Documentation required for design review 2.1.1, three copies of the plans and information stated in Vol 2, Pt 7, Ch 5, 1.3 Documentation required for design review 1.3.2 to Vol 2, Pt 7, Ch 5, 1.3 Documentation required for design review 1.3.7are to be submitted to Clasifications
Register (hereinafter referred to as 'LR') as applicable.
1.3.3
Systems. Plans in diagrammatic form showing piping arrangements, control
systems and safeguards and electrical systems for each Ship Type piping
system covered by this Chapter. The capacities of pumps and compressors
are to be included. For chilled water systems, heat load calculations
or heat balance sheets and capacity tables with condensing temperatures
covering the operating range of the refrigeration compressors are
also to be included. The tables are to be representative of the compressors
operating at the design revolutions per minute with the nominated
refrigerant.
1.3.4
Compartments. Plans showing the general arrangement of compartments, together
with a description of the Ship Type system(s) installed and the electrical
power supply systems. The plans are to indicate segregation and access
arrangements for compartments and associated control rooms/stations.
1.3.5
Risk
Assessment (RA). For Ship Type piping systems with associated
electrical power supplies and control systems, the RA report is to
address the requirements in Vol 2, Pt 7, Ch 5, 5 Risk Assessment (RA).
1.3.6
Testing
and trials procedures. A schedule of testing and trials to
demonstrate that systems are capable of operating as described in Vol 2, Pt 7, Ch 5, 3 System arrangements. Testing and trials procedures
are to comply with Vol 2, Pt 7, Ch 5, 6.3 Trials 6.3.1.
In addition, any testing programme that may be necessary to prove
the conclusions of the RA, see
Vol 2, Pt 7, Ch 5, 6.3 Trials 6.3.2.
1.3.7
Operating
Manuals. Operating Manuals are to be provided on board and
submitted for information where requested by LR. The Manuals are to
include the following information:
-
Particulars and
a description of each system.
-
Operating instructions
for all systems.
-
Procedures for
dealing with the situations identified in the RA report.