7.3.1 The
                                 plating and supporting structure are to be suitably reinforced in
                                 way of localised areas of high stress such as corners of openings,
                                 cranes, masts, equipment, fittings and other heavy or vibrating loads.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              7.3.2 Structures
                                 subject to concentrated loads are to be suitably reinforced. Where
                                 a concentration of loading on one side of a stiffener may occur, such
                                 as pillars out of line, the stiffener is to be adequately stiffened
                                 against torsion.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              7.3.3 Primary
                                 stiffening members are to be continuous and substantially bracketed
                                 at their end connections to maintain continuity of structural strength.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              7.3.4 Secondary
                                 stiffening members are to be effectively continuous and bracketed
                                 at their end connections as appropriate.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              7.3.5 Transverse
                                 rigidity is to be maintained throughout the length of the house by
                                 means of web frames, bulkheads or partial bulkheads. Particular care
                                 is to be paid when an upper tier is wider than its supporting tier
                                 and when significant loads are carried on the house top.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              7.3.6 Web
                                 frames or partial bulkheads are to be fitted in line with bulkheads
                                 or deep primary stiffeners below.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              7.3.7 Special
                                 attention is to be given to the connection of the erection to the
                                 deck in order to provide an adequate load distribution and avoid stress
                                 concentrations. The house stiffening is to align with main hull stiffening
                                 wherever possible.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              7.3.8 Where
                                 aluminium erections are arranged above a steel hull, details of the
                                 arrangements in way of the bimetallic connections are to be submitted.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              7.3.9 Adequate
                                 support under the ends of houses is to be provided in the form of
                                 webs, pillars and diaphragms or bulkheads in conjunction with reinforced
                                 deck beams. At the corners of houses and in way of supporting structures
                                 attention is to be given to the connection to the decks and inserts
                                 or equivalent arrangements should generally be fitted.