4.1.2 A report is to be submitted to LR for approval of the primary structure
in way of ice strengthening regions:
- list of plans used, including dates and versions;
- detailed description of structural model, including all modelling
assumptions;
- plots to demonstrate correct structural modelling and assigned properties;
- details of material properties used;
- details of displacement boundary conditions;
- details of the calculation of ice pressure, height and width of load patch,
and plots of load application;
- displacement and results plots that demonstrate the correct behaviour of the
structural model to the applied loads.