6.1.2 All main
and auxiliary gear units, intended for essential services, are to
be provided with means of indicating the lubricating oil supply pressure.
Audible and visual alarms are to be fitted to give warning of an appreciable
reduction in pressure of the lubricating oil supply. These alarms
are to be actuated from the outlet side of any restrictions, such
as filters, coolers, etc.