5.1.2 Equipment
used in waste systems is to be provided with local control and monitoring
arrangements.
5.1.3 Where
isolation of equipment or systems can be carried out, means of indicating
the status of isolation is to be provided at positions where the equipment
and system can be operated and monitored.
5.1.4 Instrumentation
to indicate the operational status of running and any standby equipment
is to be provided locally and at each control station.
5.1.5 All
pumps are to be provided with an indication of discharge pressure
and a low discharge pressure alarm at the control station.
5.1.8 Spaces containing waste storage or handling systems potentially containing
flammable, poisonous, toxic/corrosive, asphyxiant or irritant gases shall be fitted with
a gas detection system in accordance with Vol 2, Pt 9, Ch 11 Gas detection.