9.2.1 Each
                                 air receiver is to be fitted with a drain arrangement at its lowest
                                 part, permitting oil and water to be blown out.
                              
                              
                              
                            
                           
                           
                           
                           
                           
                           
                              
                              
                              9.2.3 Where
                                 a fixed system utilising fire-extinguishing gas is fitted, to protect
                                 a machinery space containing an air receiver(s), fitted with a fusible
                                 plug, it is recommended that the discharge from the fusible plug be
                                 piped to the open deck.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              9.2.4 Receivers
                                 used for the storage of air for the control of remotely operated valves
                                 are to be fitted with relief valves and not fusible plugs.