1.2.1 For protection
                                 against the possibility of electric shock in the event of an electrical
                                 earth fault, electrical continuity of the ship’s metallic structure
                                 is to be ensured. Metallic parts of structural panels and members
                                 are to be effectively earthed to the ship’s hull, if necessary
                                 by means of dedicated robust earthing conductor(s) having a cross-sectional
                                 area of not less than 16 mm2.