1.2.2 Units complying with the requirements of this Chapter and the relevant
                                 Parts of the Rules will be eligible for the assignment of one of the following class
                                 notations as applicable:
                                 
                                    - 
                                       Fire-fighting unit 1 (total monitor discharge capacity in brackets). 
                                    
- 
                                       Fire-fighting unit 2 (total monitor discharge capacity in brackets). 
                                    
- 
                                       Fire-fighting unit 3 (total monitor discharge capacity in brackets). 
                                    
- 
                                       Fire-fighting unit 1 (total monitor discharge capacity in brackets)
                                       with water spray. 
                                    
- 
                                       Fire-fighting unit 2 (total monitor discharge capacity in brackets)
                                       with water spray. 
                                    
- 
                                       Fire-fighting unit 3 (total monitor discharge capacity in brackets)
                                       with water spray. 
                                    
 
                              
                              
                            
                           
                           
                           
                              
                              
                              1.2.3 The notation
 Fire-fighting unit 1 or 
Fire-fighting unit 2
                                 or 
Fire-fighting unit 3 signifies that a unit complies with these Rules and
                                 is provided with the appropriate firefighting equipment described in 
Pt  3, Ch  5,  1.2 Class notations 1.2.3, with the total discharge capacity of
                                 monitors in m
3/h shown in brackets. 
                                 
                                 
                                    Table 5.1.1 Fire-fighting
                                          equipment
                                    
                                       
                                          
                                             | Equipment | Fire-fighting unit | 
                                          
                                             | 1 | 2 | 3 | 
                                          
                                             | Minimum total pump
                                                capacity, m3/h | 2400 | 7200 | 10000 | 
                                          
                                             | Minimum number of water
                                                monitors | 2 | 3 | 4 | 
                                          
                                             | Minimum discharge rate per
                                                monitor, m3/h | 1200 | 1800 | 1800 | 
                                          
                                             | Minimum height of
                                                trajectory of jets of monitors above sea level, metres | 45 | 70 | 70 | 
                                          
                                             | Minimum range of monitor
                                                jets, metres | 120 | 150 | 150 | 
                                          
                                             | Minimum fuel capacity for
                                                monitors, hours | 24 | 96 | 96 | 
                                          
                                             | Number of hose connections
                                                each side of unit | 4 | 8 | 8 | 
                                          
                                             | Number of fireman’s outfits | 4 | 8 | 8 | 
                                       
                                    
                                    
                                  
                                 
                               
                              
                              
                            
                           
                           
                           
                              
                              
                              1.2.4 The addition of the words with water spray to the notations
                                 referred to in Pt  3, Ch  5,  1.2 Class notations 1.2.3 signifies that a unit is provided with a water
                                 spray system which will provide an effective cooling spray of water over the
                                 vertical surfaces of the unit to enable it to approach a burning installation for
                                 firefighting purposes. The requirements for such a system are set out in Pt  3, Ch  5,  4 Fire protection.