6.1.1 Where foam
core materials are used in sandwich construction the properties at
elevated temperature are to be considered. Where appropriate the mechanical
properties are to be those at the maximum ambient temperature expected
under normal operating conditions.
6.1.2 Alternatively
other methods of controlling the temperature of the core may be considered,
e.g. inserts, insulation.