6.1.1 Noise levels and sound reduction indices greater than those specified in these Rules may
be considered. Not more than 10 per cent of the accommodation spaces or work spaces are
to exceed the relevant noise criteria, with a maximum exceedance limit per space/
partition of 3 dB(A).
6.1.2 If the noise levels exceed the allowable noise criteria, at least two adjacent spaces
shall be measured, including spaces on the same deck and/or on decks above and
below.
6.1.3 Where the noise level in machinery spaces (or other spaces) is greater than 85 dB(A),
entrances to such spaces shall be provided with an appropriate warning notice. If only a
minor portion of the space has such noise levels, the particular location(s) or
equipment shall be identified at eye level, visible from each direction of access.