4.1.1 Where
                                 arrangements are made for the supply of electricity from a source
                                 on shore or elsewhere, a connection box is to be installed in a position
                                 suitable for the convenient reception of flexible cables from the
                                 external source and containing a circuit-breaker or isolating switch
                                 and fuses and terminals including one earthed, of ample size and suitable
                                 shape to facilitate a satisfactory connection of three-phase external
                                 supplies with earthed neutrals.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              4.1.2 Suitable
                                 cables, permanently fixed, are to be provided, connecting the terminals
                                 in the connection box to a linked switch and/or a circuit-breaker
                                 at the main switchboard. An indicator is to be provided at the main
                                 switchboard in order to show when the cables are energised.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              4.1.3 Means
                                 are to be provided for checking the phase sequence of the incoming
                                 supply.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              4.1.4 At the
                                 connection box a notice is to be provided giving full information
                                 on the system of supply, the normal  voltage and frequency of the
                                 installation's system and the procedure for carrying out the connection.