3.4.1 Any cargo control room shall be above the
weather deck and may be located in the cargo area. The cargo control
room may be located within the accommodation spaces, service spaces
or control stations, provided the following conditions are complied
with:
-
.1 the cargo control room is a non-hazardous area;
-
.2 if the entrance complies with 3.2.4.1, the
control room may have access to the spaces described above; and
-
.3 if the entrance does not comply with 3.2.4.1,
the cargo control room shall have no access to the spaces described
above and the boundaries for such spaces shall be insulated to "A-60"
class.
3.4.2 If the cargo control room is designed to
be a non-hazardous area, instrumentation shall, as far as possible,
be by indirect reading systems and shall, in any case, be designed
to prevent any escape of gas into the atmosphere of that space. Location
of the gas detection system within the cargo control room will not
cause the room to be classified as a hazardous area, if installed
in accordance with 13.6.11.
3.4.3 If the cargo control room for ships carrying
flammable cargoes is classified as a hazardous area, sources of ignition
shall be excluded and any electrical equipment shall be installed
in accordance with chapter 10.