1 The minimum power line values of total installed MCR, in kW, for
                           different types of ships should be calculated as follows:
                        
                        
                        
                        
                        
                        
                           - 
                              
                              
                              where: 
- 
                              
                              
                              DWT is the deadweight of the ship in metric tons; and 
                               a and b are the parameters given in table 1 for
                                 tankers, bulk carriers and combination carriers.
                               
                           Table 1: Parameters a and b
                                 for determination of the minimum power line values for the different ship
                                 types
                           
                              
                                 
                                    | Ship type | a | b | 
                                 
                                    | Bulk carrier which DWT is less than 145,000 | 0.0763 | 3374.3 | 
                                 
                                    | Bulk carrier which DWT is 145,000 and over | 0.0490 | 7329.0 | 
                                 
                                    | Tanker | 0.0652 | 5960.2 | 
                                 
                                    | Combination carrier | see tanker
                                       above | 
                              
                           
                           
                         
                        
                        
                      
                     
                     
                     
                        
                        
                         2 The total installed MCR of all main propulsion engines should not be
                           less than the minimum power line value, where MCR is the value specified on the
                           EIAPP Certificate.