Statutory Documents - IMO Publications and Documents - Circulars - Maritime Safety Committee - MSC.1/Circular.1464/Rev.1 - Unified Interpretations of SOLAS Chapters II-1 and XII, of the Technical Provisions for Means of Access for Inspections (Resolution MSC.158(78)) and of the Performance Standards - Annex - 5 SOLAS Regulation II-1/41 – Main Source of Electrical Power and Lighting Systems - 5.3 SOLAS Regulation II-1/41.5.1.3, Connecting Means by Which the Main Bus Bars of the Main Source of Electrical Power are Normally Connected

5.3 SOLAS Regulation II-1/41.5.1.3, Connecting Means by Which the Main Bus Bars of the Main Source of Electrical Power are Normally Connected

Interpretation

  1 Other approved means can be achieved by:

  • .1 circuit breaker without tripping mechanism; or

  • .2 disconnecting link or switch by which bus bars can be split easily and safely.

  2 Bolted links, for example bolted bus bar sections, should not be accepted.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.