Degree of protection for electrical equipment
1 For equipment above a height of 450 mm above
the deck:
The degree of protection for electrical equipment required by
this section should have an enclosure having an ingress protection
of at least IP 55 as defined in IEC Publication 529 - Classification
of Degree of Protection provided by Enclosures, or by apparatus for
use in zone 2 areas as defined in IEC Publication 79 - Electrical
Apparatus for Explosive Gas Atmospheres (Temperature Class T3).
2 For equipment at or below a height of 450 mm
above deck:
The electrical equipment referred to in this section should
be certified "safe type" and wiring, if fitted, should be suitable
for use in zone 1 areas as defined in IEC Publication 79 - Electrical
Apparatus for Explosive Gas Atmospheres - (Gas Group II A and Temperature
Class T 3).