7.2.1 The maximum and minimum static and transient internal atmosphere
temperatures shall be defined for normal and abnormal operating conditions.
7.2.2 The maximum and minimum transient internal atmosphere temperature shall
be defined for emergency operating conditions. The following scenarios shall be
considered: loss of HVAC or cooling, fire, unintended munitions reactions, overload
of mechanical or electrical systems, loss of cryogenic material.
7.2.3 Temperature limits are to be set giving due consideration to all sources
of heating and cooling within the submarine and heat gain from solar radiation.
7.2.4 Temperatures may be defined for a compartment, or groups of compartments,
and are to include any localised heating from equipment operation.
7.2.5 The atmosphere temperatures defined shall take account of the immediate
capability and longer-term health of the embarked persons.
7.2.6 The systems, equipment and components are to be verified as being
effective and safe for the full range of internal atmosphere temperatures.
7.2.7 Atmosphere Control requirements shall be complied with.