14.2.2.1 The perimeter of the steam room may include
changing rooms, showers and toilets.
14.2.2.2 Bathrooms with direct access to suite
may be considered as part of it. In such cases, the door between suite
and the bathroom need not comply with fire safety requirements.
14.2.2.3 If a steam generator of more than 5 kW
is contained within the perimeter, the suite boundary should be constructed
to an A-0 standard, or B-0 for Short Range Yachts. If a steam generator
of more than 5 kW is not contained within the perimeter the steam
generator should be protected by A-0 standard divisions, or B-0 for
Short Range Yachts and pipes leading to the discharge nozzles should
be lagged.
14.2.2.4 If a suite arrangement contains a sauna
then the requirements contained in 14.2.1 are applicable, regardless
of the steam generator location.
14.2.2.5 All spaces within the perimeter are to
be protected by a fire detection and alarm system.