7 Determination of power set point stability
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Codes - NOx Technical Code (2008) - Technical Code on Control of Emission of Nitrogen Oxides from Marine Diesel Engines - Appendix 8 – Implementation of the direct measurement and monitoring method(Refer to 6.4 of the NOx Technical Code 2008) - 7 Determination of power set point stability

7 Determination of power set point stability

  7.1 To determine set point stability, the power coefficient of variance shall be calculated over a 10-minute interval, and the sampling rate shall be at least 1-Hz. The result shall be less than or equal to five per cent (5%).

  7.2 The formulae for calculating the coefficient of variance are as follows:

Where:

  • %C.O.V. power coefficient of variance in %
  • S.D. standard deviation
  • Ave average
  • N total number of data points sampled
  • xi, xj ith, jth value of power data point in kW
  • i index variable in standard deviation formula
  • j index variable in average formula.

Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.