5.2 Smouldering cigarette source
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - Resolutions - Assembly - IMO Resolution A.652(16) – Recommendation of Fire Test Procedures for Upholstered Furniture – (Adopted on 19 October 1989) - Annex - Recommendation of Fire Test Procedures for Upholstered Furniture - (Methods of test for the ignitability by smokers' materials of upholstered composites for seating) - 5 Apparatus - 5.2 Smouldering cigarette source

5.2 Smouldering cigarette source

 An untipped cigarette, complying with the following requirements, is needed:

  length 68 mm approximately;
  diameter 8 mm approximately;
  mass 1 g nominal;
  smouldering rate 12.0 ± 1.5 min/50 mm.

 The smouldering rate shall be verified, as follows, on one sample from each batch of 10 cigarettes used.

 Mark the cigarette, conditioned as described in 6.1, at 5 mm and 55 mm from the end to be lit. Light it as described in 8.2.1 and impale it horizontally in draught-free air on a horizontal wire spike inserted not more than 13 mm into the unlit end. Record the time taken to smoulder from the 5 mm mark to the 55 mm mark.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.