The gases to be measured shall be analysed with the following
                           instruments. For non-linear analysers, the use of linearising circuits
                           is permitted.
                        
                        
                        
                        
                           - 
                              
                              
                              
                                 .1 Carbon monoxide (CO) analysis
                              
                              
                              
                              
                              The carbon monoxide analyser shall be of the Non-Dispersive
                                 InfraRed (NDIR) absorption type.
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .2 Carbon dioxide (CO2) analysis
                                 
                              
                              
                              
                              
                              The carbon dioxide analyser shall be of the Non-Dispersive InfraRed
                                 (NDIR) absorption type.
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .3 Oxygen (O2) analysis
                                 
                              
                              
                              
                              
                              Oxygen analysers shall be of the ParaMagnetic Detector (PMD),
                                 ZiRconium DiOxide (ZRDO) or ElectroChemical Sensor (ECS) type.
                              
                              
                              
                              
                                 
                                 
                                 Note Electrochemical sensors shall be compensated for CO2 and
                                    NOx interference.
                                    
                                 
                                 
                                 
                               
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .4 Oxides of nitrogen (NOx)
                                 analysis
                                 
                              
                              
                              
                              
                              The oxides of nitrogen analyser shall be of the ChemiLuminescent
                                 Detector (CLD) or Heated ChemiLuminescent Detector (HCLD) type with
                                 a NO2/NO converter, if measured on a dry basis. If measured
                                 on a wet basis, an HCLD with converter maintained above 333 K (60°C)
                                 shall be used, provided the water quench check (see 8.2.2 of appendix 4 of this Code) is satisfied.