(1) Subject to the provisions of regulation 3, any deliberate emissions
of ozone-depleting substances shall be prohibited. Deliberate emissions
include emissions occurring in the course of maintaining, servicing,
repairing or disposing of systems or equipment, except that deliberate
emissions do not include minimal releases associated with the recapture
or recycling of an ozone-depleting substance. Emissions arising from
leaks of an ozone-depleting substance, whether or not the leaks are
deliberate, may be regulated by Parties to the Protocol of 1997.
(2) New installations which contain ozone-depleting
substances shall be prohibited on all ships, except that new installations
containing hydrochlorofluorocarbons (HCFCs) are permitted until 1
January 2020.
(3) The substances referred to in this regulation,
and equipment containing such substances, shall be delivered to appropriate
reception facilities when removed from ships.”
With respect to the completion of the IAPP certificate supplement
items 2.1.2 and 2.1.3, permanently sealed refrigeration equipment
should not be included. Permanently sealed refrigeration equipment
are equipment where there is no refrigerant charging connections or
potentially removable components.