6.3.1 Care should be taken in the erection of
                           materials and in the construction of accommodation spaces. During
                           sea trial testing, if the erection of materials is in doubt then measurements
                           should be taken on board ships for a representative selection of each
                           type of partition, floors, doors as requested in paragraph 6.2.1 and
                           to the satisfaction of the Administration.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           6.3.2 The apparent weighted sound reduction index
                           R'w should comply with the requirements of the paragraph
                           6.2.1 with tolerance of up to 3 dB.
                           
                        
                        
                        
                        
                           
                           
                           Note Field measurements should be performed according to ISO
                              140-4:1998footnote. When the area of the
                              materials tested is <10 m2, a minimum value of 10 m2 should
                              be considered for the calculation of the R'w index.