1.4.1 The approval requirements for pollution
prevention equipment specified in these Guidelines and Specifications
are summarized below:
-
.1 the 15 ppm Bilge Separator should be tested
for type approval in accordance with the procedures described in part
1 of the annex, subject to environmental tests specified in part 3
of the annex; and
-
.2 the oil content meter for the 15 ppm Bilge
Separator effluent discharge, hereinafter referred to as the 15 ppm
Bilge Alarm should be tested for type approval in accordance with
part 2 of the annex, subject to the environmental tests specified
in part 3 of the annex.