6.4.9.1 The output of the analysers shall be recorded
both during the test and during all response checks (zero and span).
This data shall be recorded on a strip chart recorder or other types
of data recording devices. Data recording precision shall be in accordance
with 5.9.7.1.
6.4.9.2 For the evaluation of the gaseous emissions,
a 1-Hertz minimum chart reading of a stable 10-minute sampling interval
of each load point shall be averaged. The average concentrations of
NOx, and if required CO2, and optionally CO,
HC and O2, shall be determined from the averaged chart
readings and the corresponding calibration data.
6.4.9.3 As a minimum, emission concentrations,
engine performance and ambient condition data shall be recorded over
the aforementioned 10-minute period.