3 Shear capacity of
the double-bottom structure in way of the foremost cargo hold
The shear capacity C of the double-bottom structure
in way of the foremost cargo hold is defined as the sum of the shear
strength at each end of:
- all floors adjacent to both hoppers, less one half of the strength
of the two floors adjacent to each stool, or transverse bulkhead if
no stool is fitted (see figure
2); and
- all double-bottom girders adjacent to both stools, or transverse
bulkheads if no stool is fitted.
The strength of girders or floors which run out and are not
directly attached to the boundary stool or hopper girder is to be
evaluated for the one end only.
Note that the floors and
girders to be considered are those inside the hold boundaries formed
by the hoppers and stools (or transverse bulkheads if no stool is
fitted). The hopper side girders and the floors directly below the
connection of the bulkhead stools (or transverse bulkheads if no stool
is fitted) to the liner bottom are not to be included.
When
the geometry and/or the structural arrangement of the double bottom
are such as to make the above assumptions inadequate, to the discretion
of the Administration or of an organization recognized by the Administration
in accordance with the provisions of SOLAS regulation
XI/1 (hereinafter referred to as "the Administration"), the
shear capacity C of the double bottom is to be calculated
according to the criteria laid down by the Administration.
In
calculating the shear strength, the net thickness of floors and girders
are to be used. The net thickness t
net, in
mm, is given by:
where:
t
|
= |
as-built
thickness, in mm, of floors and girders |
t
c
|
= |
corrosion diminution, equal to 2 mm, in general; a lower value
of t
c, may be adopted, provided that measures
are taken to the satisfaction of the Administration to justify the
assumption made.
|
3.1 Floor shear strength
The floor shear strength in way of the floor panel adjacent
to hoppers S
f1, in kN, and the floor shear
strength in way of the openings in the "outermost" bay (i.e., that
bay which is closest to hopper) S
f2, in kN,
are given by the following expressions:
where:
A
f
|
= |
sectional area, in mm2, of the floor panel adjacent
to hoppers
|
A
f,h
|
= |
net sectional area, in mm2, of the floor panels in
way of the openings in the "outermost" bay (i.e., that bay which is
closest to hopper)
|
τ
a
|
= |
allowable shear stress, in N/mm2, to be taken equal
to
|
σ
F
|
= |
minimum upper yield stress, in N/mm2, of the material
|
η
1
|
= |
1.10 |
η
2
|
= |
1.20 |
= |
η
2 may be reduced, at the discretion
of the Administration, down to 1.10 where appropriate reinforcements
are fitted to the satisfaction of the Administration.
|
3.2 Girder shear strength
The girder shear strength in way of the girder panel adjacent
to stools (or transverse bulkheads, if no stool is fitted) S
g1, in kN, and the girder shear strength in way of the largest
opening in the "outermost" bay (i.e., that bay which is closest to
stool, or transverse bulkhead, if no stool is fitted) S
g2, in kN, are given by the following expressions:
where:
A
g
|
= |
minimum sectional area, in mm2, of the girder panel
adjacent to stools (or transverse bulkheads, if no stool is fitted)
|
A
g,h
|
= |
net sectional area, in mm2, of the girder panel in
way of the largest opening in the "outermost" bay (i.e., that bay
which is closest to stool, or transverse bulkhead, if no stool is
fitted)
|
τ
a
|
= |
allowable shear stress, in N/mm2, as given in 3.1
|
η
1
|
= |
1.10 |
η
2
|
= |
1.15 |
= |
η
2 may be reduced, at the discretion
of the Administration, down to 1.10 where appropriate reinforcements
are fitted to the satisfaction of the Administration.
|
|
Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime
and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective
officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications
Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance
on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is
exclusively on the terms and conditions set out in that contract.
|
 |
|