9.10.1 Means should be provided for stopping ventilating
fans serving machinery and working spaces and for closing all doorways,
ventilators, annular spaces around funnels and other openings to such
spaces. These means should be capable of being operated from outside
such spaces in case of fire.
9.10.2 Machinery driving forced and induced draught
fans, electric motor pressurization fans, oil fuel transfer pumps,
oil fuel unit pumps and other similar fuel pumps should be fitted
with remote controls situated outside the space concerned so that
they may be stopped in the event of a fire arising in the space in
which they are located.
9.10.3 Every oil fuel suction pipe from a storage,
settling or daily service tank situated above the double bottom should
be fitted with a cock or valve capable of being closed from outside
the space concerned in the event of a fire arising in the space in
which such tanks are situated. In the special case of deep tanks situated
in any shaft or pipe tunnel, valves on the tanks should be fitted
but control in event of fire may be effected by means of an additional
valve on the pipeline or lines outside the tunnel or tunnels.