Section 7.3.1
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - Circulars - Maritime Safety Committee - MSC/Circular.911 – Interpretations of Fire Protection-Related Provisions of the HSC Code – (Adopted on 4 June 1999) - Annex - Interpretations of Fire Protection-Related Provisions of the HSC Code - Section 7.3.1

Section 7.3.1

  Separating partial bulkheads of spaces

 If a space is divided by partial bulkheads into two (or more) smaller areas such that they form enclosed spaces, then the enclosed spaces should be surrounded by bulkheads and decks in accordance with tables7.4-1 and 7.4-2, as applicable. However, if the separating bulkheads of such spaces are at least 30 % open, then the spaces may be considered as the same space.

  Acceptance of cabinets

 Cabinets having a deck area of less than 2 m2 may be accepted as part of the space they serve provided they have open ventilation to the space and do not contain any material or equipment which could be a fire risk.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.