Clasification Society Rulefinder 2020 - Version 9.33 - Fix
Common Structural Rules - Common Structural Rules for Bulk Carriers and Oil Tankers, January 2019 - Part 1 General Hull Requirements - Chapter 3 Structural Design Principles - Section 7 Structural Idealisation - Symbols |
||
![]() SymbolsSymbols For symbols not defined in this section, refer to Ch 1, Sec 4. ϕw : Angle, in deg, between the stiffener or primary supporting member web and the attached plating, see Figure 14. ϕw is to be taken equal to 90 deg if the angle is greater than or equal to 75 deg.
s : Stiffener spacing, in mm, as defined in [1.2]. S : Primary supporting member spacing, in m, as defined in [1.2]. a : Length, in mm, of EPP as defined in [2.1.1]. b : Breadth, in mm, of EPP as defined in [2.1.1]. hstf : Stiffener height, including the face plate, in mm. tp : Net thickness of attached plate, in mm. tw : Net web thickness, in mm. For bulb profiles, see [1.4.1]. bf : Breadth of flange, in mm, see Ch 3, Sec 2, Figure 2. For bulb profiles, see [1.4.1]. tf : Net thickness of flange, in mm. PSM : Primary Supporting Member. EPP : Elementary Plate Panel. LCP : Load Calculation Point. |
||
|
||
|