10.1.1 Each unit should be provided with survival
craft of such aggregate capacity as will accommodate twice the total
number of persons on the unit, including:
-
.1 rigid totally enclosed motor propelled and
fire protected survival craft of such capacity as will accommodate
all persons on the unit; and
-
.2 survival craft, capable of floating and breaking
free in the event of the unit becoming submerged, of such capacity
as will accommodate all persons on board.
10.1.2 In complying with the provisions above,
not less than two survival craft should be provided.
10.1.3 Survival craft should be constructed and
equipped so as to comply with the requirements of Regulations 5, 6,
7 and 11 or Regulations 15, 16 and 17 of Chapter III of the 1974 SOLAS
Convention for lifeboats and liferafts, respectively. These Regulations
should not preclude the use of new design and technology which has
been found acceptable to the Administration. When, in the opinion
of the Administration, any items of equipment required by Regulations
11 and 17 are unnecessary, the Administration may permit them to be
dispensed with.
10.1.4 Survival craft should be so marked that
they can be properly and readily identified.