10.3.1 Each unit should carry, on each side of
                           the unit, one or more lifeboats complying with the requirements of
                           the LSA Code of such aggregate capacity as will accommodate the total
                           number of persons on board. Alternatively, the Administration may
                           accept one or more free-fall lifeboats, complying with the requirements
                           of section 4.7 of the LSA Code, capable of being free-fall launched
                           over the end of the unit of such aggregate capacity as will accommodate
                           the total number of persons on board.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           10.3.2 In addition, each unit should carry a liferaft
                           or liferafts, complying with the requirements of the LSA Code and
                           approved to the actual operating height, capable of being launched
                           on either side of the unit and of such aggregate capacity as will
                           accommodate the total number of persons on board. If the liferaft
                           or liferafts cannot be readily transferred for launching on either
                           side of the unit, the total capacity available on each side should
                           be sufficient to accommodate the total number of persons on board.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           10.3.3 Where the survival craft are stowed in
                           a position which is more than 100 m from the stem or stern, each unit
                           should carry, in addition to the liferafts as provided in paragraph
                           10.3.2, a liferaft stowed as far forward or aft, or one as far forward
                           and another as far aft, as is reasonable and practicable. Notwithstanding
                           paragraph 10.6.6, such liferaft or liferafts may be securely fastened
                           so as to permit manual release.