6.1.1 To ensure compliance with this Standard,
the following should be carried out by qualified coating inspectors
certified to NACE Coating Inspector Level 2, FROSIO Inspector level
III or equivalent as verified by the Administrationfootnote.
6.1.2 Coating inspectors should inspect surface
preparation and coating application during the coating process by
carrying out, as a minimum, those inspection items identified in section
6.2 to ensure compliance with this Standard. Emphasis should be placed
on initiation of each stage of surface preparation and coatings application,
as improper work is extremely difficult to correct later in the coating
progress. Representative structural members should be non-destructively
examined for coating thickness. The inspector should verify that appropriate
collective measures have been carried out.
6.1.3 Results from the inspection should be recorded
by the inspector and should be included in the CTF (refer to annex
2, Example of Daily Log and Non-conformity Report).