The following shall be carried out by the Administration
                           prior to reviewing the Coating Technical File for the ship subject
                           to this Standard:
                        
                        
                        
                        
                           - 
                              
                              
                              
                                 .1 check that the Technical Data Sheet and Statement
                                 of Compliance or Type Approval Certificate comply with the Standard;
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .2 check that the coating identification on representative
                                 containers is consistent with the coating identified in the Technical
                                 Data Sheet and Statement of Compliance or Type Approval Certificate;
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .3 check that the inspector is qualified in accordance
                                 with the qualification standards in paragraph 6.1.1;
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .4 check that the inspector's reports of surface
                                 preparation and the coating's application indicate compliance with
                                 the manufacturer's Technical Data Sheet and Statement of Compliance
                                 or Type Approval Certificate; and
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .5 monitor implementation of the coating inspection
                                 requirements.