9.2.1 operating conditions. Humidity limits are to be set taking into account internal air
pressure and temperature variation for normal and abnormal operating conditions.
9.2.2 Humidity limits are to be set giving due consideration to all sources of water vapour
within the submarine.
9.2.3 The range of humidity variation during submarine operation at sea and alongside is to
be defined such that equipment can be tested to ensure it can accommodate the cyclic
variation or be provided with suitable protection.
9.2.4 The maximum and minimum transient internal humidity shall be defined for
emergency operating conditions. The following scenarios shall be considered: loss of
HVAC or cooling, leaks from steam or other high temperature systems,
9.2.5 Where submarines are to be inactive for periods of time, suitable arrangements are to
be provided to protect key equipment against the effects of condensation.
9.2.6 The atmosphere humidity defined shall take account of the impact on embarked
persons.
9.2.7 The systems, equipment and components are to be verified as being effective and safe
for the full range of internal atmosphere humidity.
9.2.8 Atmosphere Control requirements shall be complied with.