2.2.1 The analyser specifications shall be consistent
with 1.6, 1.7, 1.8, 1.9 and 1.10 of appendix
3 of this Code.
2.2.2 The analyser range shall be such that the
measured emission value is within 15% – 100% of the range used.
2.2.3 The analysing equipment shall be installed
and maintained in accordance with manufacturers’ recommendations
in order to meet the requirements of 1.7, 1.8, 1.9, and 1.10 of appendix 3 of this Code and sections 7 and
9 of appendix 4 of this Code.