14.4.1 Requirements of this section shall apply
to ships carrying products for which those paragraphs are listed in
column "i" in the table of chapter 19.
14.4.2 Suitable respiratory and eye protection
for emergency escape purposes shall be provided for every person on
board, subject to the following:
-
.1 filter-type respiratory protection is unacceptable;
-
.2 self-contained breathing apparatus shall have
at least a duration of service of 15 min; and
-
.3 emergency escape respiratory protection shall
not be used for firefighting or cargo-handling purposes and shall
be marked to that effect.
14.4.3 One or more suitably marked decontamination
showers and eyewash stations shall be available on deck, taking into
account the size and layout of the ship. The showers and eyewashes
shall be operable in all ambient conditions.
14.4.4 The protective clothing required under
14.3.2.2 shall be gastight.