11.5.1 Enclosed spaces meeting the criteria of
cargo machinery spaces in 1.2.10, and the cargo motor room within
the cargo area of any ship, shall be provided with a fixed fire-extinguishing
system complying with the provisions of the FSS Code and taking into
account the necessary concentrations/application rate required for
extinguishing gas fires.
11.5.2 Enclosed spaces meeting the criteria of
cargo machinery spaces in chapter 3.3, within the cargo area of ships
that are dedicated to the carriage of a restricted number of cargoes,
shall be protected by an appropriate fire-extinguishing system for
the cargo carried.
11.5.3 Turret compartments of any ship shall be
protected by internal water spray, with an application rate of not
less than 10 ℓ/m2/min of the largest projected horizontal
surface. If the pressure of the gas flow through the turret exceeds
4 MPa, the application rate shall be increased to 20 ℓ/m2/min.
The system shall be designed to protect all internal surfaces.