3.2.1 The Navy is to define EMP strengths and frequency spectrum.
3.2.2 The submarine, systems, equipment and components that are required to operate within
an EMP environment in extreme conditions are to be identified. They shall be able to
operate with defined levels of electromagnetic interference or be fitted with
suitable protection measures.
3.2.3 The submarine, systems, equipment and components that are required to survive and/or
operate after exposure to an EMP environment in extreme conditions are to be
identified. They shall be able to operate after being exposed to an EMP environment
or be fitted with suitable protection measures.
3.2.4 Procedures are to be in place to protect the embarked persons from the direct effects
of EMP and effects of EMP on systems, equipment and components.