Statutory Documents - IMO Publications and Documents - Circulars - Maritime Safety Committee - MSC.1/Circular.1437 – Unified Interpretations of SOLAS Regulation II-2/21.4 – (31 May 2012) - Annex – Unified Interpretations to SOLAS Regulation II-2/21.4 – (To be used in conjunction with the interim explanatory notes for the assessment of passenger ship systems' capabilities after a fire or flooding casualty (MSC.1/Circ.1369)) - Regulation II-2/21.4 – Fire and flooding casualty, electrical cables

Regulation II-2/21.4 – Fire and flooding casualty, electrical cables

 Electrical cables complying with standard IEC 60092-359 may be considered to remain operational in a space affected by a flooding casualty, provided they have no connections, no joints, no equipment connected to them, etc., within such space or such connections, joints and devices have a degree of protection IPX8 in accordance with standard IEC 60529 (head of water expected at their location for a period not inferior to that estimated for the safe return to port).


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.