Clasification Society Rulefinder 2020 - Version 9.33 - Fix
Common Structural Rules - Common Structural Rules for Bulk Carriers and Oil Tankers, January 2019 - Part 1 General Hull Requirements - Chapter 9 Fatigue - Section 3 Fatigue Evaluation - Symbols

Symbols

For symbols not defined in this section, refer to Ch 1, Sec 4.

(i) : Suffix which denotes load case HSM, FSM, BSR-P, BSR-S, BSP-P, BSP-S, OST-P or OST-S specified in Ch 4, Sec 2, [3].
  • i1’ denotes load case: HSM-1, FSM-1, BSR-1P, BSR-1S, BSP-1P, BSP-1S, OST-1P or OST-1S.
  • i2’ denotes load case: HSM-2, FSM-2, BSR-2P, BSR-2S, BSP-2P, BSP-2S, OST-2P or OST-2S.
(j) : Suffix which denotes loading condition:
  • Full load or normal ballast for oil tankers as defined in Ch 9, Sec 1, [6.2].
  • Full load homogeneous, full load alternate, normal ballast or heavy ballast for bulk carriers as defined in Ch 9, Sec 1, [6.3].

TC : Time in corrosive environment, in years, according to Table 5.

TD : Design life, in years, to be taken as 25 years.

TDF : Design fatigue life, in year, as defined in Ch 9, Sec 1.

TF : Fatigue life, in year, calculated according to [5].

m : Inverse slope of the design S-N curve, as given in Table 2 for in-air environment and in Table 3 for corrosive environment.
  • The inverse slope for S-N curves in-air environment changes from m to m+2 at N = 107 cycles.

nLC : Number of applicable loading conditions, as defined in Ch 9, Sec 1, [6.2] and Ch 9, Sec 1, [6.3].

fc : Correction factor as defined in Ch 9, Sec 1, [5.1.2].

fthick : Correction factor for plate thickness effect given in [3.3].

fmean, i(j) : Correction factor for mean stress effect given in [3.2]


Copyright 2020 Clasification Society, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasification Society, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasification Society'. Clasification Society Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasification Society entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.