1 The number of openings in watertight bulkheads
                           shall be reduced to the minimum compatible with the design and proper
                           working of the ship, satisfactory means shall be provided for closing
                           these openings.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           2.1 Where pipes, scuppers, electric cables, etc.,
                           are carried through watertight bulkheads, arrangements shall be made
                           to ensure the watertight integrity of the bulkheads.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           2.2 Valves not forming part of a piping system
                           shall not be permitted in watertight bulkheads.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           2.3 Lead or other heat sensitive materials shall
                           not be used in systems which penetrate watertight bulkheads, where
                           deterioration of such systems in the event of fire would impair the
                           watertight integrity of the bulkheads.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           3 No doors, manholes, or access openings are permitted
                           in watertight transverse bulkheads dividing a cargo space from an
                           adjoining cargo space, except as provided in paragraph 9.1 and in regulation 14.
                           
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           4 Subject to paragraph 10, not more than one door,
                           apart from the doors to shaft tunnels, may be fitted in each watertight
                           bulkhead within spaces containing the main and auxiliary propulsion
                           machinery including boilers serving the needs of propulsion. Where
                           two or more shafts are fitted, the tunnels shall be connected by an
                           intercommunicating passage. There shall be only one door between the
                           machinery space and the tunnel spaces where two shafts are fitted
                           and only two doors where there are more than two shafts. All these
                           doors shall be of the sliding type and shall be so located as to have
                           their sills as high as practicable. The hand gear for operating these
                           doors from above the bulkhead deck shall be situated outside the spaces
                           containing the machinery.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           5.1 Watertight doors, except as provided in paragraph
                           9.1 or regulation 14, shall
                           be power-operated sliding doors complying with the requirements of
                           paragraph 7 capable of being closed simultaneously from the central
                           operating console at the navigation bridge in not more than 60 s with
                           the ship in the upright position.
                           
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           5.2 The means of operation whether by power or
                           by hand of any power-operated sliding watertight door shall be capable
                           of closing the door with the ship listed to 15° either way. Consideration
                           shall also be given to the forces which may act on either side of
                           the door as may be experienced when water is flowing through the opening,
                           applying a static head equivalent to a water height of at least 1
                           m above the sill on the centreline of the door.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           5.3 Watertight door controls, including hydraulic
                           piping and electric cables, shall be kept as close as practicable
                           to the bulkhead in which the doors are fitted, in order to minimize
                           the likelihood of them being involved in any damage which the ship
                           may sustain. The positioning of watertight doors and their controls
                           shall be such that if the ship sustains damage within one fifth of
                           the breadth of the ship, as defined in regulation
                              2, such distance being measured at right angles to the centreline
                           at the level of the deepest subdivision draught, the operation of
                           the watertight doors clear of the damaged portion of the ship is not
                           impaired.
                           
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           6 All power-operated sliding watertight doors
                           shall be provided with means of indication which will show at all
                           remote operating positions whether the doors are open or closed. Remote
                           operating positions shall only be at the navigation bridge as required
                           by paragraph 7.1.5 and at the location where hand operation above
                           the bulkhead deck is required by paragraph 7.1.4.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           7.1 Each power-operated sliding watertight door:
                        
                        
                        
                        
                           - 
                              
                              
                              
                                 .1 shall have a vertical or horizontal motion;
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .2 shall, subject to paragraph 10, be normally
                                 limited to a maximum clear opening width of 1.2 m. The Administration
                                 may permit larger doors only to the extent considered necessary for
                                 the effective operation of the ship provided that other safety measures,
                                 including the following, are taken into consideration:
                              
                              
                              
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .3 shall be fitted with the necessary equipment
                                 to open and close the door using electric power, hydraulic power,
                                 or any other form of power that is acceptable to the Administration;
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .4 shall be provided with an individual hand-operated
                                 mechanism. It shall be possible to open and close the door by hand
                                 at the door itself from either side, and in addition, close the door
                                 from an accessible position above the bulkhead deck with an all round
                                 crank motion or some other movement providing the same degree of safety
                                 acceptable to the Administration. Direction of rotation or other movement
                                 is to be clearly indicated at all operating positions. The time necessary
                                 for the complete closure of the door, when operating by hand gear,
                                 shall not exceed 90 s with the ship in the upright position;
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .5 shall be provided with controls for opening
                                 and closing the door by power from both sides of the door and also
                                 for closing the door by power from the central operating console at
                                 the navigation bridge;
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .6 shall be provided with an audible alarm, distinct
                                 from any other alarm in the area, which will sound whenever the door
                                 is closed remotely by power and which shall sound for at least 5 s
                                 but no more than 10 s before the door begins to move and shall continue
                                 sounding until the door is completely closed. In the case of remote
                                 hand operation it is sufficient for the audible alarm to sound only
                                 when the door is moving. Additionally, in passenger areas and areas
                                 of high ambient noise the Administration may require the audible alarm
                                 to be supplemented by an intermittent visual signal at the door; and
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .7 shall have an approximately uniform rate of
                                 closure under power. The closure time, from the time the door begins
                                 to move to the time it reaches the completely closed position, shall
                                 in no case be less than 20 s or more than 40 s with the ship in the
                                 upright position.
                              
                              
                              
                            
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           7.2 The electrical power required for power-operated
                           sliding watertight doors shall be supplied from the emergency switchboard
                           either directly or by a dedicated distribution board situated above
                           the bulkhead deck. The associated control, indication and alarm circuits
                           shall be supplied from the emergency switchboard either directly or
                           by a dedicated distribution board situated above the bulkhead deck
                           and be capable of being automatically supplied by the transitional
                           source of emergency electrical power required by regulation 42.3.1.3 in the event of
                           failure of either the main or emergency source of electrical power.
                           
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           7.3 Power-operated sliding watertight doors shall
                           have either:
                        
                        
                        
                        
                           - 
                              
                              
                              
                                 .1 a centralized hydraulic system with two independent
                                 power sources each consisting of a motor and pump capable of simultaneously
                                 closing all doors. In addition, there shall be for the whole installation
                                 hydraulic accumulators of sufficient capacity to operate all the doors
                                 at least three times, i.e. closed-open-closed, against an adverse
                                 list of 15º. This operating cycle shall be capable of being carried
                                 out when the accumulator is at the pump cut-in pressure. The fluid
                                 used shall be chosen considering the temperatures liable to be encountered
                                 by the installation during its service. The power operating system
                                 shall be designed to minimize the possibility of having a single failure
                                 in the hydraulic piping adversely affect the operation of more than
                                 one door. The hydraulic system shall be provided with a low-level
                                 alarm for hydraulic fluid reservoirs serving the power-operated system
                                 and a low gas pressure alarm or other effective means of monitoring
                                 loss of stored energy in hydraulic accumulators. These alarms are
                                 to be audible and visual and shall be situated on the central operating
                                 console at the navigation bridge; or
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .2 an independent hydraulic system for each door
                                 with each power source consisting of a motor and pump capable of opening
                                 and closing the door. In addition, there shall be a hydraulic accumulator
                                 of sufficient capacity to operate the door at least three times, i.e.
                                 closed-open-closed, against an adverse list of 15º. This operating
                                 cycle shall be capable of being carried out when the accumulator is
                                 at the pump cut-in pressure. The fluid used shall be chosen considering
                                 the temperatures liable to be encountered by the installation during
                                 its service. A low gas pressure group alarm or other effective means
                                 of monitoring loss of stored energy in hydraulic accumulators shall
                                 be provided at the central operating console on the navigation bridge.
                                 Loss of stored energy indication at each local operating position
                                 shall also be provided; or
                              
                              
                              
                            
                           - 
                              
                              
                              
                                 .3 an independent electrical system and motor
                                 for each door with each power source consisting of a motor capable
                                 of opening and closing the door. The power source shall be capable
                                 of being automatically supplied by the transitional source of emergency
                                 electrical power as required by regulation
                                    42.4.2 – in the event of failure of either the main or
                                 emergency source of electrical power and with sufficient capacity
                                 to operate the door at least three times, i.e. closed-open-closed,
                                 against an adverse list of 15º.
                                 
                              
                              
                              
                            
                        
                        
                        
                        
                        For the systems specified in paragraphs 7.3.1, 7.3.2 and 7.3.3,
                           provision should be made as follows: Power systems for power-operated
                           watertight sliding doors shall be separate from any other power system.
                           A single failure in the electric or hydraulic power-operated systems
                           excluding the hydraulic actuator shall not prevent the hand operation
                           of any door.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           7.4 Control handles shall be provided at each
                           side of the bulkhead at a minimum height of 1.6 m above the floor
                           and shall be so arranged as to enable persons passing through the
                           doorway to hold both handles in the open position without being able
                           to set the power closing mechanism in operation accidentally. The
                           direction of movement of the handles in opening and closing the door
                           shall be in the direction of door movement and shall be clearly indicated.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           7.5 As far as practicable, electrical equipment
                           and components for watertight doors shall be situated above the bulkhead
                           deck and outside hazardous areas and spaces.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           7.6 The enclosures of electrical components necessarily
                           situated below the bulkhead deck shall provide suitable protection
                           against the ingress of water.footnote
                           
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           7.7 Electric power, control, indication and alarm
                           circuits shall be protected against fault in such a way that a failure
                           in one door circuit will not cause a failure in any other door circuit.
                           Short circuits or other faults in the alarm or indicator circuits
                           of a door shall not result in a loss of power operation of that door.
                           Arrangements shall be such that leakage of water into the electrical
                           equipment located below the bulkhead deck will not cause the door
                           to open.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           7.8 A single electrical failure in the power operating
                           or control system of a power-operated sliding watertight door shall
                           not result in a closed door opening. Availability of the power supply
                           should be continuously monitored at a point in the electrical circuit
                           as near as practicable to each of the motors required by paragraph
                           7.3. Loss of any such power supply should activate an audible and
                           visual alarm at the central operating console at the navigation bridge.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           8.1 The central operating console at the navigation
                           bridge shall have a "master mode" switch with two modes of control:
                           a "local control" mode which shall allow any door to be locally opened
                           and locally closed after use without automatic closure, and a "doors
                           closed" mode which shall automatically close any door that is open.
                           The "doors closed" mode shall automatically close any door that is
                           open. The "doors closed" mode shall permit doors to be opened locally
                           and shall automatically re-close the doors upon release of the local
                           control mechanism. The "master mode" switch shall normally be in the
                           "local control" mode. The "doors closed" mode shall only be used in
                           an emergency or for testing purposes. Special consideration shall
                           be given to the reliability of the "master mode" switch.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           8.2 The central operating console at the navigation
                           bridge shall be provided with a diagram showing the location of each
                           door, with visual indicators to show whether each door is open or
                           closed. A red light shall indicate a door is fully open and a green
                           light shall indicate a door is fully closed. When the door is closed
                           remotely the red light shall indicate the intermediate position by
                           flashing. The indicating circuit shall be independent of the control
                           circuit for each door.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           8.3 It shall not be possible to remotely open
                           any door from the central operating console.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           9.1 If the Administration is satisfied that such
                           doors are essential, watertight doors of satisfactory construction
                           may be fitted in watertight bulkheads dividing cargo between deck
                           spaces. Such doors may be hinged, rolling or sliding doors but shall
                           not be remotely controlled. They shall be fitted at the highest level
                           and as far from the shell plating as practicable, but in no case shall
                           the outboard vertical edges be situated at a distance from the shell
                           plating which is less than one fifth of the breadth of the ship, as
                           defined in regulation 2, such
                           distance being measured at right angles to the centreline at the level
                           of the deepest subdivision draught.
                           
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           9.2 Should any such doors be accessible during
                           the voyage, they shall be fitted with a device which prevents unauthorized
                           opening. When it is proposed to fit such doors, the number and arrangements
                           shall receive the special consideration of the Administration.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           10 Portable plates on bulkheads shall not be permitted
                           except in machinery spaces. The Administration may permit not more
                           than one power-operated sliding watertight door in each watertight
                           bulkhead larger than those specified in paragraph 7.1.2 to be substituted
                           for these portable plates, provided these doors are intended to remain
                           closed during navigation except in case of urgent necessity at the
                           discretion of the master. These doors need not meet the requirements
                           of paragraph 7.1.4 regarding complete closure by hand-operated gear
                           in 90 s.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           11.1 Where trunkways or tunnels for access from crew
                           accommodation to the machinery spaces, for piping, or for any other purpose are carried
                           through watertight bulkheads, they shall be watertight and in accordance with the
                           requirements of regulation 16-1. The access to at least one end of each such tunnel or
                           trunkway, if used as a passage at sea, shall be through a trunk extending watertight to
                           a height sufficient to permit access above the bulkhead deck. The access to the other
                           end of the trunkway or tunnel may be through a watertight door of the type required by
                           its location in the ship. Such trunkways or tunnels shall not extend through the first
                           subdivision bulkhead abaft the collision bulkhead.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           11.2 Where it is proposed to fit tunnels piercing
                           watertight bulkheads, these shall receive the special consideration
                           of the Administration.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           11.3 Where trunkways in connection with refrigerated
                           cargo and ventilation or forced draught trunks are carried through
                           more than one watertight bulkhead, the means of closure at such openings
                           shall be operated by power and be capable of being closed from a central
                           position situated above the bulkhead deck.