Clasification Society Rulefinder 2016 - Version 9.25
Clasification Society Rules and Regulations - Rules and Regulations for the Classification of Offshore Units, January 2016 - Part 11 PRODUCTION, STORAGE AND OFFLOADING OF LIQUEFIED GASES IN BULK - Chapter 18 Operating Requirements - Section 2 Storage and transfer |
||
![]() Section 2 Storage and transfer2.1 Product suitability2.1.1 The Operator shall ascertain that the quantity and characteristics of each product to be loaded are within the limits indicated in the Loading and Stability Information booklet provided for in Pt 11, Ch 2, 1.2 Freeboard and stability 1.2.5. 2.1.2 Care should be taken to avoid dangerous chemical reactions if cargoes are
mixed. This is of particular significance in respect of:
2.2 Storage of cargo at low temperature2.2.1 When carrying cargoes at low temperatures:
2.3 Cargo transfer operations2.3.1 A pre cargo operations meeting shall take place between shuttle tanker personnel and the persons responsible at the transfer facility of the ship unit. Information exchanged shall include the details of the intended cargo transfer operations and emergency procedures. A recognised industry checklist shall be completed for the intended cargo transfer and effective communications shall be maintained throughout the operation. 2.3.2 Essential cargo handling controls and alarms shall be checked and tested prior to cargo transfer operations. 2.4 Cargo sampling2.4.1 Any cargo sampling shall be conducted under the supervision of an Officer who shall ensure that protective clothing appropriate to the hazards of the cargo is used by everyone involved in the operation. 2.4.2 When taking liquid cargo samples the Officer shall ensure that the sampling equipment is suitable for the temperatures and pressures involved, including cargo pump discharge pressure if relevant. 2.4.3 The Officer shall ensure that any cargo sample equipment used is connected properly to avoid any cargo leakage. 2.4.4 After sampling operations are completed, the Officer shall ensure that any sample valves used are closed properly and the connections used are correctly blanked. |
||
|
||
|