The volumetric heeling moment for a cargo hold which is
“filled" and trimmed in accordance with regulation
3(a), is based on a grain shift of 15°. It is to be especially
noted that there is only one condition which is deemed to be “filled".
Any other condition, even one which is only minimally different, is
considered to be “partly filled", and the volumetric heeling
moment should be based upon a 25° grain shift. It is evident that
the volumetric heeling moment curves in some grain loading booklets
do not recognize this distinction. They show the uppermost point on
the volumetric heeling moment curve for the partly filled compartment
to be coincident with the volumetric heeling moment for the filled
compartment. The following guideline is intended to caution those
involved in the preparation of grain loading booklets, against making
this error.