.1 The inlet and outlet valves of oil-fired thermal
oil heaters and exhaust-fired thermal oil heaters shall be controllable
from outside the compartment where they are situated. As an alternative,
an arrangement for quick gravity drainage of the thermal oil contained
in the system into a collecting tank is acceptable.
.2 Heating of liquid cargoes with flash points
below 60°C shall be arranged by means of a separate secondary
system, located completely within the cargo area.
However, a single circuit system may be accepted on the following
conditions:
- system is so arranged that a positive pressure in the coil shall
be at least 3 m water column above the static head of the cargo when
circulating pump is not in operation,
- the thermal oil system expansion tank shall be fitted with high
and low level alarms,
- means shall be provided in the thermal oil system expansion tank
for detection of flammable cargo vapours. Portable equipment may be
accepted.
- valves for the individual heating coils shall be provided with
locking arrangement to ensure that the coils are under stake pressure
at all times.
.3 The thermal oil circulating pumps shall be
arranged for emergency stopping from a position outside the space
where they are situated.
.4 Vents from expansion tanks and thermal oil
storage tanks of thermal oil heating plants shall be led to open deck.