Annex 4 - Guidance Materials Matrix for Accommodation Spaces, Service Spaces and Control Stations

Table Summarising Categories of Passenger Yacht and Standards of Stability and Survivability, LSA Scales, Maximum Persons Carried and Other Related Matters.

Type of Space Control Stations Stairway Enclosures Corridors Accommodation Areas Service spaces and Garage Spaces Balconies see note (10) Included in Calorific value Calculation Included in Fire Volume Calculation
Category Of Space 1 4 2 3 5,9,11 10 1 - 9 1 - 9
Material
(A) Floor coverings Annex 1, Part 2 Annex 1, Part 5

Annex 1, Part 2

Annex 1, Part 5

Annex 1, Part 2

Annex 1, Part 2 (PYC 6.4 refers) Annex 1, Part 2 Annex 1, Part 5 Annex 1, Part 2 Except natural hardwood decking systems See Note (10)    
(B) Primary deck coverings Annex 1, Part 5

Annex 1, Part 2

Annex 1, Part 5

Annex 1, Part 2

Annex 1, Part 5

Annex 1, Part 2

Annex 1, Part 5

Annex 1, Part 2

Annex 1, Part 5

Annex 1, Part 2

Annex 1, Part 5

Annex 1, Part 2

   
(C) Exposed surfaces of walls and ceilings, panel surfaces and ceiling linings, including paints, varnishes, fabrics & veneers (see note 16) Annex 1, Part 5

Annex 1, Part 2 see notes (5)

Annex 1, Part 5

Annex 1, Part 2 see notes (5)

Annex 1, Part 5

Annex 1, Part 2 see notes (5)

Annex 1, Part 5

Annex 1, Part 2 see notes (5)

Annex 1, Part 5

Annex 1, Part 2 see notes (5)

Annex 1, Part 5

Annex 1, Part 2 see notes (5)

✓ (except Balconies)
(D) Skirting Board Annex 1 Part 2

Annex 1 Part 5 see notes (5) & (6)

Annex 1 Part 2

Annex 1 Part 5 see note (6)

Annex 1 Part 2

Annex 1 Part 5 see note (6)

Annex 1 Part 2

Annex 1 Part 5 see note (6)

Annex 1 Part 2

Annex 1 Part 5 see note (6)

No Applicable Requirements  
(E) Combustible facings, mouldings, decorations Annex 1 Part 2

Annex 1 Part 5 see notes (5) & (6)

Annex 1 Part 2

Annex 1 Part 5 see note (6)

Annex 1 Part 2

Annex 1 Part 5 see note (6)

Annex 1 Part 2

Annex 1 Part 5 see note (6)

Annex 1 Part 2

Annex 1 Part 5 see note (6)

Annex 1 Part 2

Annex 1 Part 5 see note (6)

 
(F) Partial Bulkhead Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1    
(G) Wall panel/Lining Annex 1, Part 1 see note (15) Annex 1, Part 1 see note (15) Annex 1, Part 1 see note (15) Annex 1, Part 1 see note (15) Annex 1, Part 1 see note (15) Annex 1, Part 1 see note (15)    
(H) Concealed panel surface (see note 17) Annex 1, Part 5 Annex 1, Part 5 Annex 1, Part 5 Annex 1, Part 5 Annex 1, Part 5 No Applicable Requirements  
(I) Draught stops Annex 1, Part 1 see note (15) Annex 1, Part 1 see note (15) Annex 1, Part 1 see note (15) Annex 1, Part 1 see note (15) Annex 1, Part 1 see note (15) Not applicable    
(J) Grounds & supports (see note 15) Annex 1, Part 1 see notes (14) & (15) Annex 1, Part 1 see notes (14) & (15) Annex 1, Part 1 see notes (14) & (15) Annex 1, Part 1 see notes (14) & (15) Annex 1, Part 1 see notes (14) & (15) Annex 1, Part 1 see notes (14) & (15)    
(K) Insulation Annex 1, Part 1 see note (12) Annex 1, Part 1 see note (12) Annex 1, Part 1 see note (12) Annex 1, Part 1 see note (12) Annex 1, Part 1 see note (12) Annex 1, Part 1 see note (12)    
(L) Insulation surface Annex 1, Part 5 see note (13) Annex 1, Part 5 see note (13) Annex 1, Part 5 see note (13) Annex 1, Part 5 see note (13) Annex 1, Part 5 see note (13) Annex 1, Part 5 see note (13)    
M) Curtains and other suspended textiles Annex 1, Part 7 Annex 1, Part 7 Annex 1, Part 7 Annex 1, Part 7 Annex 1, Part 7 Not applicable    
(N) Upholstered furniture (including (Sofas & Chairs) see note (5) see notes (2) & (4) See Note(11) No Applicable Requirements No Applicable Requirements Annex 1, Part 8 see note (9)    
(O) Case furniture (desks, wardrobes, dressing tables, bureaux, dressers etc.) see note (5) Not allowed Not allowed see note (17) see note (17) No Applicable Requirements    
(P) Free standing furniture (tables etc.) see note (5) Not allowed Not allowed see note (17) see note (17) see note (9)    
Q) Window box surface Annex 1, Part 5

Annex 1, Part 2 see note (1)

Annex 1, Part 5

Annex 1, Part 2 see note (1)

Annex 1, Part 5

Annex 1, Part 2 see note (1)

Annex 1, Part 5

Annex 1, Part 2 see note (1)

Annex 1, Part 5

Annex 1, Part 2 see note (1)

Annex 1, Part 5

Annex 1, Part 2 see note (1)

✓ see note (1)
(R) GRP surfaces in private Bathroom/Toilet Modules Not applicable Not applicable Not applicable Annex 1, Part 5

Annex 1, Part 2

Not applicable Not applicable
(S) Light fixtures In general no certification required, but to be looked at on a case by case basis, in particular when at ceiling or fixed to bulkhead    
(T) Waste receptacles Not allowed Not allowed Not allowed Non-combustible Non-combustible see note (3) Non-combustible    
(U) Object d'art, planters, paintwork (NEVER TO REDUCE ESCAPE WIDTHS) Not allowed see notes (7) & (8) see note(7) No Applicable Requirements Not allowed No Applicable Requirements    

 (to be read in conjunction with Chapter 6 of the Code & MSC/Circ. 1120, Annex, Interpretation of SOLAS Regulations II-2/5 .3 & 6. For guidance only, actual requirements should be taken from the text within chapter 6 of the Code)

Description FTP Code Part Test Procedure
Non-combustibility test FTP Code Annex 1, Part 1 ISO 1182:2010
Smoke and toxicity test FTP Code Annex 1, Part 2 ISO 5659-2: 2012 and reference to MSC/Circ. 1120
"A","B" & "F" class divisions FTP Code Annex 1, Part 3 -
Test for fire door control systems FTP Code Annex 1, Part 4 -
Test for surface flammability FTP Code Annex 1, Part 5 -
Test for primary deck covering FTP Code Annex 1, Part 5 -
Test for vertically supported textiles FTP Code Annex 1, Part 7 -
Test for upholstered furniture FTP Code Annex 1, Part 8 -
Test for bedding components FTP Code Annex 1, Part 9 -
Determination of calorific potential SOLAS II-2/5.3.2.2 ISO 1716:2002
       
Note that where the words 'No Applicable Requirements' appear, although no compliance is required by the Regulations, use of materials having restricted fire risk as per applicable requirements, is recommended  
note(1): The windows box has to have a non-combustible structure. Where the strucutre is faced with a combustible veneer, this item is to be included in the fire volume calculation.  
note(2): Furniture in stairway enclosures shall be limited to seating. It shall be fixed, limited to six seats on each deck in each stairway enclosure, of restricted fire risk, and shall not restrict the passenger escape route.  
note(3): Reference can be made to IACS UI SC166  
note(4): These items are to be constructed with frames of non-combustible materials and, if upholstered are to comply with FTP Annex 1, Part 8  
note(5): Such spaces were not originally meant to be outfitted as accommodation spaces and fire volume calculations were in fact not required. Should they be constructed as such they should be treated as spaces of restricted fire risk as defined in SOLAS II-2/3.40  
note(6): FTP Code, Annex 1, Parts 2 and 5 are applicable only to paints, varnishes and other finishes (Reg. II-2/6.2) (i.e. not veneers or substrate).  
note(7): To be kept to a minimum, be fixed and have properties that are not readily ignitible.  
note(8): Large paintings that form the majority of the bulkhead are to have low frame spread surface.  
note(9): Refer to PYC 6.3 (21), (22) & (23) for details regarding Furniture and furnishings on cabin balconies.  
note(10): For open deck spaces other than balconies attention is to be paid to MSC.1/Circ.1274  
note (11): Not allowed in cabin corridors. In other corridors (i.e. corridors not forming part of an Escape Route), notes 2 and 4 apply.  
note (12): Insulating materials located in cargo spaces, mail rooms and refrigerated compartments of service spaces need not be non-combustible. SOLAS II-2/5.3.1.1 refers.  
note (13): Combustible vapour barriers and adhesives used in conjunction with insulation shall be kept to the minimum quantity practicable. SOLAS II-2/5.3.1.1 refers.  
note (14): Linings, grounds, draught stops and ceilings in mail rooms, baggage rooms, saunas or refrigerated compartments need not be non-combustible. SOLAS II-2/5.3.1.2.1 refers.  
note (15): Grounds in concealed or inaccessible spaces in accommodation, service spaces and control stations shall have low flame spread characteristics in accordance with FTP Code Annex 1, Part 5. SOLAS II-2/5.3.2.4.1.2 refers.  
note (16): See PYC 6.3 (18) for details regarding the possible relaxation of Low Flame-spread characteristics in areas appropriated for the use of the Owners anf Guests, subject to agreement by the Flag Administration.  
note (17): Refer to PYC 6.7(1) (i) & (ii) for detailed requirements  
   

Copyright 2020 Clasification Society, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasification Society, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasification Society'. Clasification Society Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasification Society entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.