Calculation
|
Data to be provided to or accepted by
the Society
|
Still Water Shear Force
(SWSF)
|
1. The read-out points (frame
locations) for the SWSF calculations. These points are normally selected at
the position of the transverse bulkhead or other obvious boundaries.
Additional read-out points may be specified between the bulkheads of long
holds or tanks or between container stacks.
|
2. Shear force correction factors and
method of application.
|
3. The permissible seagoing and
harbour SWSF limits at the read-out points specified in (1). Where
appropriate, additional sets of permissible SWSF values may be
specified.
|
Still Water Bending
Moment (SWBM)
|
1. The read-out points (frame
locations) for the SWBM calculations. These points are normally selected at
the position of the transverse bulkhead, mid-hold or other obvious
boundaries.
|
2. The permissible seagoing and
harbour SWBM limits at the read-out points specified in (1). Where
appropriate, additional sets of permissible SWBM values may be
specified.
|
Still Water Torsion
Moment (SWTM), where applicable
|
1. The read-out points (frame
locations) for the SWTM calculations.
|
2. The permissible limits at the
read-out points specified in (1).
|