4.2.1 Where applicable, allowance should be made
for temporary point loads. Such allowances should include at least
the force exerted by a load (person) of 100 kg at mid-span on any
pipe or more than 100 mm nominal outside diameter.
4.2.2 Pipes should be protected from mechanical