Annex 2 - Guidance Materials Matrix for Accommodation Spaces, Service Spaces and Control Stations
Clasification Society 2024 - Version 9.40
Statutory Documents - MCA Publications - Yacht Code - January 2019 Edition - Part B - Passenger Yacht Code (up to 36 passengers) - Annex 2 - Guidance Materials Matrix for Accommodation Spaces, Service Spaces and Control Stations

Annex 2 - Guidance Materials Matrix for Accommodation Spaces, Service Spaces and Control Stations

Type of Space Control Stations Stairway Enclosures Corridors Accommo-dation Areas Service spaces and Garage Spaces Balconies see note (10) Included in Calorific value Calculation Included in Fire Volume Calculation
Material ▼ Category Of Space ► 1 4 2 3 5,9,11 10 1-9 1-9
(A) Floor coverings No Applicable Requirements Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 2
(PYC 6.4 refers)
No Applicable Requirements Annex 1, Part 5
Annex 1, Part 2
Except natural hardwood decking systems See Note (10)
   
(B) Primary deck coverings Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
   
(C) Exposed surfaces of walls and ceilings, panel surfaces and ceiling linings, including paints, varnishes, fabrics and veneers (see note 16) Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2

(except Balconies)
(D) Skirting Board Annex 1, Part 2
Annex 1, Part 5
see note (6)
Annex 1, Part 2
Annex 1, Part 5
see note (6)
Annex 1, Part 2
Annex 1, Part 5
see note (6)
Annex 1, Part 2
Annex 1, Part 5
see note (6)
Annex 1, Part 2
Annex 1, Part 5
see note (6)
No Applicable Requirements  
(E) Combustible facings, mouldings, decorations Annex 1, Part 2
Annex 1, Part 5
see note (6)
Annex 1, Part 2
Annex 1, Part 5
see note (6)
Annex 1, Part 2
Annex 1, Part 5
see note (6)
Annex 1, Part 2
Annex 1, Part 5
see note (6)
Annex 1, Part 2
Annex 1, Part 5
see note (6)
Annex 1, Part 2
Annex 1, Part 5
see note (6)
(F) Partial Bulkhead Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1    
(G) Wall panel/Lining Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1    
(H) Concealed panel surface Annex 1, Part 5 Annex 1, Part 5 Annex 1, Part 5 Annex 1, Part 5 Annex 1, Part 5 No Applicable Requirements  
(I) Draught stops Annex 1, Part 1
see note (14)
Annex 1, Part 1
see note (14)
Annex 1, Part 1
see note (14)
Annex 1, Part 1
see note (14)
Annex 1, Part 1
see note (14)
Not applicable    
(J) Grounds and supports Annex 1, Part 1
see note (15)
Annex 1, Part 1
see note (15)
Annex 1, Part 1
see note (15)
Annex 1, Part 1
see note (15)
Annex 1, Part 1
see notes (14) and (15)
Annex 1, Part 1
see notes and (15)
   
(K) Insulation Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1 Annex 1, Part 1
see note (12)
Annex 1, Part 1    
(L) Insulation surface Annex 1, Part 5
see note (13)
Annex 1, Part 5
see note (13)
Annex 1, Part 5
see note (13)
Annex 1, Part 5
see note (13)
Annex 1, Part 5
see note (13)
Annex 1, Part 5
see note (13)
   
(M) Curtains and other suspended textiles Annex 1, Part 7
see note (5)
Annex 1, Part 7 Annex 1, Part 7 see note (17) Annex 1, Part 7 Not applicable    
(N) Upholstered furniture (including (Sofas and Chairs) see note (5) see notes (2) and (4) see note (11) see note (17) see note (5) Annex 1, Part 8
see note (9)
   
(O) Case furniture (desks, wardrobes, dressing tables, bureaux, dressers etc.) see note (5) Not allowed Not allowed see note (17) No Applicable Requirements No Applicable Requirements    
(P) Free standing furniture (tables etc.) see note (5) Not allowed Not allowed see note (17) No Applicable Requirements see note (9)    
(Q) Window box surface Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2
Annex 1, Part 5
Annex 1, Part 2

see note (1)
(R) GRP surfaces in private Bathroom/Toilet Modules Not applicable Not applicable Not applicable Annex 1, Part 5
Annex 1, Part 2
Not applicable Not applicable
(S) Light fixtures In general no certification required, but to be looked at on a case by case basis, in particular when at ceiling or fixed to bulkhead    
(T) Waste receptacles Not allowed Not allowed Not allowed Non-combustible see note (3) Non-combustible see note (3) Non-combustible see note (3)    
(U) Object d'art, planters, paintwork (NEVER TO REDUCE ESCAPE WIDTHS) Not allowed see notes (7) and (8) see notes (7) and (8) see note (8) Not allowed No Applicable Requirements    

 (to be read in conjunction with Chapter 6 of the Code and MSC/Circ.1120, Annex, Interpretation of SOLAS II-2/5 .3 and 6. For guidance only, actual requirements shall be taken from the text within chapter 6 of the Code)

Description FTP Code Part Test Procedure
Non-combustibility test FTP Code Annex 1, Part 1 ISO 1182:2010
Smoke and toxicity test FTP Code Annex 1, Part 2 ISO 5659-2: 2012 and reference to MSC/Circ. 1120
"A","B" & "F" class divisions FTP Code Annex 1, Part 3 -
Test for fire door control systems FTP Code Annex 1, Part 4 -
Test for surface flammability FTP Code Annex 1, Part 5 -
Test for primary deck covering FTP Code Annex 1, Part 5 -
Test for vertically supported textiles FTP Code Annex 1, Part 7 -
Test for upholstered furniture FTP Code Annex 1, Part 8 -
Test for bedding components FTP Code Annex 1, Part 9 -
Determination of calorific potential SOLAS II-2/5.3.2.2 ISO 1716:2002
         
  Note that where the words 'No Applicable Requirements' appear, although no compliance is required by the Regulations, use of materials having restricted fire risk in accordance with applicable requirements, is recommended  
  note(1): The windows box shall have a non-combustible structure. Where the structure is faced with a combustible veneer, this item shall be included in the fire volume calculation.  
  note(2): Furniture in stairway enclosures shall be limited to seating. It shall be fixed, limited to six seats on each deck in each stairway enclosure, of restricted fire risk, and shall not restrict the passenger escape route  
  note(3): Refer to PYC 6.2(32) for detailed requirements  
  note(4): These items shall be constructed with frames of non-combustible materials and, if upholstered are to comply with FTP Annex 1, Part 8  
  note(5): Such spaces were not originally meant to be outfitted as accommodation spaces and fire volume calculations were in fact not required by SOLAS. Should they be constructed as such they shall be treated as spaces of restricted fire risk as defined in 6.7(1)(d)  
  note(6): FTP Code, Annex 1, Parts 2 and 5 are applicable only to paints, varnishes and other finishes (Reg. II-2/6.2) (i.e. not veneers or substrate).  
  note(7): To be kept to a minimum, be fixed and have properties that are not readily ignitable.  
  note(8): Large artworks that form the majority of the bulkhead are to have low frame spread surface.  
  note(9): Refer to PYC 6.3 (21), (22) and (23) for details regarding Furniture and furnishings on cabin balconies.  
  note(10): For open deck spaces other than balconies, attention shall be paid to MSC.1/Circ.1274 when adjacent to LSA  
  note(11): Not allowed in cabin corridors. In other corridors (i.e. corridors not forming part of an Escape Route), notes 2 and 4 apply.  
  note(12): Insulating materials located in cargo spaces, mail rooms and refrigerated compartments of service spaces need not be non-combustible. SOLAS II-2/5.3.1.1 refers.  
  note(13): Combustible vapour barriers and adhesives used in conjunction with insulation shall be kept to the minimum quantity practicable. SOLAS II-2/5.3.1.1 refers.  
  note(14): Linings, grounds, draught stops and ceilings in mail rooms, baggage rooms, saunas or refrigerated compartments need not be non-combustible. SOLAS II-2/5.3.1.2.1 refers.  
  note(15): Grounds in concealed or inaccessible spaces in accommodation, service spaces and control stations shall have low flame spread characteristics in accordance with FTP Code Annex 1, Part 5. SOLAS II-2/5.3.2.4.1.2 refers.  
  note(16): See PYC 6.3 (18) for details regarding the possible relaxation of Low Flame-spread characteristics in areas appropriated for the use of the Owners and passengers, subject to agreement by the Flag Administration.  
  note(17): Refer to PYC 6.7(1)(d)and for detailed requirements where the space shall be treated as spaces of restricted fire risk.  
  The content of Annex 2 is generously provided by Lloyds Register to the appreciation of the Red Ensign Group (REG).  
     

Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.