This chapter details the specifications for fixed foam fire-extinguishing
systems for the protection of machinery spaces in accordance with regulation II-2/10.4.1.1.2 of the
Convention, cargo spaces in accordance with regulation II-2/10.7.1.1, cargo
pump-rooms in accordance with regulation II-2/10.9.1.2 and vehicle, special category and ro-ro spaces
in accordance with regulation II-2/20.6.1.3. This chapter does not apply to cargo pump-rooms of chemical
tankers carrying liquid cargoes referred to in regulation II-2/1.6.2 of the Convention,
unless the Administration specifically accepts the use of these systems
based on additional tests with alcohol-based fuel and alcohol resistant
foam. Unless expressly provided otherwise, the requirements of this
chapter shall apply to ships constructed on or after 1 January 2014.