▸ Recirculate – more residence time may be needed.
▸ Flush system with hot water, re-engage and recirculate.
▸ Recirculate at lower flow rate.
▸
Inspect unit for bypass.
▸ Open, clean, and inspect
system to determine cause of failure. Repair and service OWS. Repair,
service or replace OCM Unclog or replace drains and/or piping to manufacturer’s
and/or to system design standards.
▸ Retrofit with
polishing and particulate filters (for acute conditions).
▸
Upgrade to a 107(49) unit (after considering the capacity, age, condition
and/or quality of the existing OWS).
▸ Consult manufacturers’
manual(s) for filter/coalescer replacement.
Note:
Consider designing and retrofitting the system for the addition of
post-treatment modular polishing and particle filtering technology.
Also, consider upgrading a 60(33) unit to a 107(49) unit. Specific
recommendations for a particular post-treatment retrofit or an OWS
system upgrade depend on the ship’s circumstances.