Airlocks should be provided to allow crew members to pass
from contaminated areas (such as the engine-room and open deck) to
the accommodation through a double set of doors where one must be
closed before the next can be opened. The space between these doors
should be supplied with filtered air with a slight overpressure. One
airlock between the open deck and accommodation and one between the
engine-room and accommodation is considered acceptable.